Model |
RSV-8A |
RSV-12A |
|
Power Supply |
DC100V~DC350V + AC 220V/1Ph/50Hz(60Hz) |
|||
Heating |
Capacity (kW) |
9.3 |
14.5 |
|
Test Condition |
DB/WB |
7℃ / 6℃ |
||
water inlet /outlet |
30℃ / 35℃ |
|||
Rated power consumption |
W (withoutwatercyclepump) |
2.2 |
3.4 |
|
City power 220V |
input power (W) |
164 |
367 |
|
voltage (V) |
225 |
221 |
||
current (A) |
0.73 |
1.66 |
||
Solar PV panel |
input power (W) |
2036 |
3033 |
|
voltage (V) |
186 |
259 |
||
current (A) |
10.95 |
11.71 |
||
Solar PV panel |
Specification/QTY/ Connect Way |
300W /10 PCS / 5 pcs Series & 2 parallel
|
300W /14pcs / 7pcs Series & 2 parallel |
|
Simulation test running time |
2 hours |
2 hours |
||
after Open Solar PV panel array, |
2036/2200*100%= 92.5% (save energy) |
3033/3400*100%=89.2%(save energy) |
|
Model |
RSV-8A |
RSV-12A |
|
Power Supply |
DC100V~DC350V + AC 220V/1Ph/50Hz(60Hz) |
|||
Cooling |
Capacity |
8 kW |
12 kW |
|
Test Condition |
DB/WB |
35℃ / 24℃ |
||
water inlet /outlet |
7℃ / 12℃ |
|||
Rated power consumption |
W(withoutwatercyclepump) |
2.8 |
4.1 |
|
City power 220V |
input power (W) |
168 |
370 |
|
voltage (V) |
225 |
223 |
||
current (A) |
0.75 |
1.66 |
||
Solar PV panel |
input power (W) |
2632 |
3730 |
|
voltage (V) |
176 |
245 |
||
current (A) |
14.95 |
15.22 |
||
Solar PV panel |
Specification/QTY/ Connect Way |
300W /10 PCS / 5 pcs Series & 2 parallel
|
300W /14pcs / 7pcs Series & 2 parallel |
|
Simulation test running time |
2 hours |
2 hours |
||
after Open Solar PV panel array, |
2632/2800*100%=94% ( save energy) |
3730/4100*100%=91.0% (save energy) |
Leave us Message